Canton FairSourcing
Visit the HEBEI SHANGHONG METERS TECHNOLOGY CO.,LTD store

S.H.Meters Electromagnetic Flow Meter

7/10 fairsForeign Trade Company
S.H.Meters Electromagnetic Flow Meter
Price on request

The supplier hasn’t listed a price. We can get their current prices and MOQ.

Service
From $29 per supplier (Verify)
You get
Phone and video verification, a quote sheet and a written report
Turnaround
3 business days
Contact details
Sent to you once your request is confirmed

If we can't reach the supplier within 3 business days, we refund the fee.

From the supplier

Technical performance parameters:

main power AC220V 50Hz /DC24V/3.6V Power consumption <15W(Supporting power consumption with sensors) Display and buttons Display in Chinese and English, can display instantaneous flow, cumulative flow and alarm display (excitation open circuit alarm, empty pipe alarm, flow limit alarm). 4 membrane touch switches for data setting counter Forward total, reverse total output signal Analog output Two-way two-way, fully isolated 0~10mA/4~20mA Load resistance: 0 ~ 1.5kΩ when 0 ~ 10mA; 0 ~ 750Ω when 4 ~ 20mA Frequency output Forward and reverse flow output, the upper limit of output frequency can be set within 1 ~ 5000Hz. Open collector bidirectional output of transistor with photoelectric isolation. External power supply is not greater than 35V, the maximum current of the collector when conducting is 50mA. Alarm Output Two open-collector alarm outputs with photoelectric isolation transistors. The external power supply is not greater than 35V, and the maximum current of the collector when it is turned on is 250mA. Alarm status: fluid empty pipe, excitation disconnection, flow overrun. Pulse output Forward and reverse flow output, the upper limit of output pulse can reach 5000CP / S. The pulse equivalent is 0.0001 ~ 1.0m³ / P. The pulse width is automatically set to 20ms or square wave. Open collector output of transistor with photoelectric isolation. External power supply is not greater than 35V, the maximum current of the collector when conducting is 50mA Matching accuracy ± 0.5% of market value, optional ± 0.2% or 1% of indicated value Damping time constant Continuous variable from 0 ~ 100s (90%) time grading optional communication Optional RS232C or RS485 serial communication interface, HART communication protocol, with anti-lightning protection Loss of power The internal design of the instrument has a power-off clock, which can store 16 drop-out records (10 years) Protection level IP65 Explosion-proof mark Exs[ia]ia||cT5

Lining material:

material Main performance Polyurethane rubber 1. Very good wear resistance coal slurry, mud, ore slurry, etc. 2. Not resistant to acid, alkaline and other corrosive or high temperature media 3. There must be no negative pressure in the pipeline Neoprene 1. Very good elasticity and wear resistance 2. Capable of measuring domestic sewage, non-corrosive industrial sewage PH value: in the range of 6/7/8, temperature below 80 ℃ liquid 3. There must be no negative pressure in the pipeline Teflon F-4 PTFE 1. Boiling-resistant hydrochloric acid, sulfuric acid, nitric acid, aqua regia, concentrated alkali and various organic solutions 2. Strong abrasion resistance and poor bonding performance 3. There must be no negative pressure in the pipeline Perchloroethylene propylene F-46(PTFE) 1. On the basis of all functions of PTFE, the temperature of non-corrosive liquid can be increased within 140 degrees 2. Not resistant to fuming nitric acid, butyl lithium 3. There must be no negative pressure in the pipeline Silicone fluoride lining Temperature resistance: 70 degrees, mainly high temperature. It can be used to measure hot water in heating systems, and is not resistant to corrosion.

Electromagnetic flowmeter electrode material:

material material Corrosion performance 316L electrode Application: domestic / industrial water, sewage PH value: within 6/7/8 Not applicable: corrosive media such as hydrofluoric acid / hydrochloric acid / chlorine / iodine HB Application: certain concentration of hydrofluoric acid and other oxidizing acids and non-oxidizing hydrochloric acid, alkali solution with a concentration of not less than 70% sodium hydroxide. PH value: within 5/6/7/8 Not applicable: Oxidizing acids such as nitric acid HC Application: corrosion resistance to oxidizing salts or environments containing other oxidants, especially to seawater. PH value is within: 6/7/8/9 Not applicable: hydrochloric acid, dilute sulfuric acid, phosphoric acid and other reducing acids and chlorides Ti Application: chloride, hypochlorite, sea water, oxidizing acid. PH value: within the range of 6/7/8/9/10 Not applicable: hydrochloric acid, sulfuric acid and other acidic media Ta Application: concentrated hydrochloric acid, nitric acid, sulfuric acid and other acid liquids, including boiling hydrochloric acid and nitric acid. PH value: within 3/4/5/6 Not applicable: alkali, hydrofluoric acid, fuming sulfuric acid Pt Various acids, bases, salts. Not included: Royal Water

About the supplier

HEBEI SHANGHONG METERS TECHNOLOGY CO.,LTD

Main products: Other Instrument and Meters

  • Exhibited at 7 recent Canton Fairs
  • Foreign Trade Company
  • Founded 2019
  • Canton Fair Premium Supplier
  • National high-tech enterprise
  • 1 certificate on file
See all products from this supplier →
Supplier
HEBEI SHANGHONG METERS TECHNOLOGY CO.,LTD
Shijiazhuang, Hebei, China
63
trust
  • Exhibited at 7 recent Canton Fairs
  • Foreign Trade Company
  • Founded 2019
  • Canton Fair Premium Supplier
Canton Fair booth: 8.0K25-26 · General Machinery, Small Processing Machinery and Industrial Accessories (140th session)

Similar products from other suppliers

Add a few to compare, then request quotes from all of them at once.

Price on request
MOQ 100 · Verify for $29
Get a quote