See what’s includedHide breakdown
- FOB goods (100)
- $15,000
- Ocean freight + handling (3.8 CBM, volume guessed from price)
- $1,150
- US duty (3.5%)
- $525
- Section 301 tariff (25.0%)
- $3,750
- Customs fees (MPF/HMF)
- $71
Estimate in USD to a US port using category averages, rates as of 2026-09. Other countries on request. A quote from our desk uses real carton sizes, freight and the exact tariff line.
- FOB goods (100)
- $15,000
- Ocean freight + handling (3.8 CBM, volume guessed from price)
- $1,150
- US duty (3.5%)
- $525
- Section 301 tariff (25.0%)
- $3,750
- Customs fees (MPF/HMF)
- $71
Estimate in USD to a US port using category averages, rates as of 2026-09. Other countries on request. A quote from our desk uses real carton sizes, freight and the exact tariff line.
Verify from $29 · written report in 3 business days · 100% refund if unreachable

See what’s includedHide breakdown
- FOB goods (100)
- $15,000
- Ocean freight + handling (3.8 CBM, volume guessed from price)
- $1,150
- US duty (3.5%)
- $525
- Section 301 tariff (25.0%)
- $3,750
- Customs fees (MPF/HMF)
- $71
Estimate in USD to a US port using category averages, rates as of 2026-09. Other countries on request. A quote from our desk uses real carton sizes, freight and the exact tariff line.
- FOB goods (100)
- $15,000
- Ocean freight + handling (3.8 CBM, volume guessed from price)
- $1,150
- US duty (3.5%)
- $525
- Section 301 tariff (25.0%)
- $3,750
- Customs fees (MPF/HMF)
- $71
Estimate in USD to a US port using category averages, rates as of 2026-09. Other countries on request. A quote from our desk uses real carton sizes, freight and the exact tariff line.
Verify from $29 · written report in 3 business days · 100% refund if unreachable
From the supplier
Items Specifications Accuracy ±1% of reading at rates >0.2 mps Repeatability 0.2% Principle Transmit time Velocity ±32m/s Pipe Size DN15mm-DN6000mm Display LCD with backlight, display accumulated flow/heat, instantaneous flow/heat, velocity, time etc. Signal Output 1 way 4-20mA output 1 way OCT pulse output 1 way relay output Signal Input 3 way 4-20mA input achieve to heat measurement by connecting PT100 platinum resistor Other Functions Automatically record the positive,negative,net totalizer flow rate and heat. Automatically record the time of power-on/off and flow rate of the last 30 times.Replenish by hand or read the datas through Modbus communication protocol. Pipe Material Carbon Steel, stainless steel, cast iron, cement pipe, copper, PVC, aluminum, FRP etc. Liner is allowed Straight Pipe Section Upstram: 10D; Downsteam:5D; From the pump:30D (D means outer diameter) Liquid Types All kinds of clean and pure liquids. Liquid Temperature Standard: -30℃ ~ 90℃ ,High-temperature:-30℃ ~ 160℃ Liquid Turbidity Less than 10000ppm, with a little bubble Flow Direction Bi-directional measuring, net flow/heat measuring Environment Temperature Main Unit: -30℃ ~ 80℃ Transducer: -30℃ ~ 160℃, Temperature transducer: select on enquiry Environment Humidity Main Unit: 85% RH Transducer: standard is IP65, IP68(optional) Cable Twisted Pair Line, standard length of 5m, can be extended to 500m (not recommended); Contact the manufacturer for longer cable requirement. RS-485 interface, transmission distance up to 1000m Power Supply DC24V Power Consumption Less than 1.5W Communication MODBUS RTU RS485
From the supplier
Items Specifications Accuracy ±1% of reading at rates >0.2 mps Repeatability 0.2% Principle Transmit time Velocity ±32m/s Pipe Size DN15mm-DN6000mm Display LCD with backlight, display accumulated flow/heat, instantaneous flow/heat, velocity, time etc. Signal Output 1 way 4-20mA output 1 way OCT pulse output 1 way relay output Signal Input 3 way 4-20mA input achieve to heat measurement by connecting PT100 platinum resistor Other Functions Automatically record the positive,negative,net totalizer flow rate and heat. Automatically record the time of power-on/off and flow rate of the last 30 times.Replenish by hand or read the datas through Modbus communication protocol. Pipe Material Carbon Steel, stainless steel, cast iron, cement pipe, copper, PVC, aluminum, FRP etc. Liner is allowed Straight Pipe Section Upstram: 10D; Downsteam:5D; From the pump:30D (D means outer diameter) Liquid Types All kinds of clean and pure liquids. Liquid Temperature Standard: -30℃ ~ 90℃ ,High-temperature:-30℃ ~ 160℃ Liquid Turbidity Less than 10000ppm, with a little bubble Flow Direction Bi-directional measuring, net flow/heat measuring Environment Temperature Main Unit: -30℃ ~ 80℃ Transducer: -30℃ ~ 160℃, Temperature transducer: select on enquiry Environment Humidity Main Unit: 85% RH Transducer: standard is IP65, IP68(optional) Cable Twisted Pair Line, standard length of 5m, can be extended to 500m (not recommended); Contact the manufacturer for longer cable requirement. RS-485 interface, transmission distance up to 1000m Power Supply DC24V Power Consumption Less than 1.5W Communication MODBUS RTU RS485
About the supplier
Main products: Sensors, Electronic instruments, Other Instrument and Meters, Special instruments, Oval gear flow meter, Oval gear meter
- ✓Exhibited at 4 recent Canton Fairs
- ✓Industry and Trade Company
- ✓Founded 2005
- ✓Canton Fair Premium Supplier
- ✓National high-tech enterprise
- ✓1 certificate on file
- Exhibited at 4 recent Canton Fairs
- Industry and Trade Company
- Founded 2005
- Canton Fair Premium Supplier