Aerial 2core Drop Wire telephone cable CCS or BC pe or pvc jacket unshielded outdoor drop cable
ZHUHAI SURELINK COMMUNICATION CABLE CO.,LTD.
The supplier hasn’t listed a price. We can get their current prices and MOQ.
Verify from $29 · written report in 3 business days · 100% refund if not satisfied

Aerial 2core Drop Wire telephone cable CCS or BC pe or pvc jacket unshielded outdoor drop cable
ZHUHAI SURELINK COMMUNICATION CABLE CO.,LTD.The supplier hasn’t listed a price. We can get their current prices and MOQ.
Verify from $29 · written report in 3 business days · 100% refund if not satisfied
About this product
- Size: 10cm
- Color: black
- Insulation material: Other
- Conductor material: AluminumOther
- Voltage type: LowVoltage
- Technique: Other
- Exports to: Africa, Middle East, Southeast Asia, South Asia, Central Asia, USA and Canada, Latin America, Russia, EU, Other European Countries
About this product
- Size: 10cm
- Color: black
- Insulation material: Other
- Conductor material: AluminumOther
- Voltage type: LowVoltage
- Technique: Other
- Exports to: Africa, Middle East, Southeast Asia, South Asia, Central Asia, USA and Canada, Latin America, Russia, EU, Other European Countries
Product details
| Size | 10cm |
|---|---|
| Color | black |
| Insulation material | Other |
| Conductor material | AluminumOther |
| Voltage type | LowVoltage |
| Technique | Other |
| Application | TelecommunicationOverhead |
Product details
| Size | 10cm |
|---|---|
| Color | black |
| Insulation material | Other |
| Conductor material | AluminumOther |
| Voltage type | LowVoltage |
| Technique | Other |
| Application | TelecommunicationOverhead |
From the supplier
1. CONDUCTORS
Material: 18 AWG Electrolytic, minimum 99,90% pure copper (Cu), considering the Silver (Ag) as copper for the calculation of this percentage
Density: 8.89 g/cm³ at 20ºC
Dimensions: Nominal Diameter: 1.024 mm (18AWG)
Specific Section: 0.824 mm squre
Min. Diameter : 1.014 mm
Max. Diameter: 1.034 mm
2. Conductor traction resistance: Minimum 45.8 kg/mm squre
Minimum elongation of a conductor at 1500 mm: 0.86%
Electrical properties at 20ºC:
Resistivity: Max. 0.01793 Ohm mm²/m
Density/Resistivity: Max. 0.15940 g/m²
DC Resistance at 20ºC: Max. 44.5 Ohms/km-Pair
3. INSULATION
Type: PVC 75ºC
Flame resistance: According to 1581-1080.VW-1 (Vertical Wire) Flame Test
Maximum Temperature: 75ºC
Physical requirements:
a) Before Aging:
- Breaking Strength: Minimum 13.8 MPa (1.41 kg/mm²)
- Elongation until Breaking: Minimum 150%
b) Aging in a Hot Air Chamber at 121ºC ± 1ºC during 168 hrs:
- Breaking Strength (percentage of the value without aging): Maximum 120
Minimum 80
- Elongation until Breaking (minimum percentage of the value without aging): 75
c) Aging by immersion in oil at 70ºC ± 1ºC during 4 hrs:
- Minimum Breaking Strength (percentage of the value without aging): 85
- Elongation until Breaking (minimum percentage of the value without aging): 85
4. Nominal dimensions and tolerances:
A = Height : 3.5mm ± 0.2 mm
B = Width : 7.0mm ± 0.4 mm
C = Distance between conductors : 3.5mm ± 0.4mm
D = Thickness of the nerve : 1.3mm ± 0.3 mm
Insulation thickness: Nominal: 1.24mm
Minimum at any point: 0.9mm
Polarity identification: Red trace of 0.8mm + 0.4 mm – 0.1mm, extruded longitudinally over one of the conductors of the drop wire
Approximate weight: 39 kg/km
Email:sales@zhsurelink.com
Wechat: surelink2008
WhatsApp: +86 13926923676
https://www.zhsurelink.com
From the supplier
1. CONDUCTORS
Material: 18 AWG Electrolytic, minimum 99,90% pure copper (Cu), considering the Silver (Ag) as copper for the calculation of this percentage
Density: 8.89 g/cm³ at 20ºC
Dimensions: Nominal Diameter: 1.024 mm (18AWG)
Specific Section: 0.824 mm squre
Min. Diameter : 1.014 mm
Max. Diameter: 1.034 mm
2. Conductor traction resistance: Minimum 45.8 kg/mm squre
Minimum elongation of a conductor at 1500 mm: 0.86%
Electrical properties at 20ºC:
Resistivity: Max. 0.01793 Ohm mm²/m
Density/Resistivity: Max. 0.15940 g/m²
DC Resistance at 20ºC: Max. 44.5 Ohms/km-Pair
3. INSULATION
Type: PVC 75ºC
Flame resistance: According to 1581-1080.VW-1 (Vertical Wire) Flame Test
Maximum Temperature: 75ºC
Physical requirements:
a) Before Aging:
- Breaking Strength: Minimum 13.8 MPa (1.41 kg/mm²)
- Elongation until Breaking: Minimum 150%
b) Aging in a Hot Air Chamber at 121ºC ± 1ºC during 168 hrs:
- Breaking Strength (percentage of the value without aging): Maximum 120
Minimum 80
- Elongation until Breaking (minimum percentage of the value without aging): 75
c) Aging by immersion in oil at 70ºC ± 1ºC during 4 hrs:
- Minimum Breaking Strength (percentage of the value without aging): 85
- Elongation until Breaking (minimum percentage of the value without aging): 85
4. Nominal dimensions and tolerances:
A = Height : 3.5mm ± 0.2 mm
B = Width : 7.0mm ± 0.4 mm
C = Distance between conductors : 3.5mm ± 0.4mm
D = Thickness of the nerve : 1.3mm ± 0.3 mm
Insulation thickness: Nominal: 1.24mm
Minimum at any point: 0.9mm
Polarity identification: Red trace of 0.8mm + 0.4 mm – 0.1mm, extruded longitudinally over one of the conductors of the drop wire
Approximate weight: 39 kg/km
Email:sales@zhsurelink.com
Wechat: surelink2008
WhatsApp: +86 13926923676
https://www.zhsurelink.com
About the supplier
Main products: Lan Cable, UTP CAT6,adss cable,fiber cable,ftth cable,plc splitter,fiber terminal box,ODF,fiber patch cord,fiber pigtail,fiber cabinet,microduct,fiber clamp
- ✓Exhibited at 4 recent Canton Fairs
- ✓Foreign Trade Company
- ✓Founded 2008
- ✓1 certificate on file
Electronics & Appliance exhibitors show in Phase 1 of the Canton Fair, 15 to 19 October 2026.
- Exhibited at 4 recent Canton Fairs
- Foreign Trade Company
- Founded 2008
- 1 certificate on file














