Binghuo New Energy Biogas torch, emergency torch, biogas torch Kitchen waste, papermaking industry
SUMEC INTERNATIONAL TECHNOLOGY CO.,LTD
The supplier hasn’t listed a price. We can get their current prices and MOQ.
Verify from $29 · written report in 3 business days · 100% refund if not satisfied

Binghuo New Energy Biogas torch, emergency torch, biogas torch Kitchen waste, papermaking industry
SUMEC INTERNATIONAL TECHNOLOGY CO.,LTDThe supplier hasn’t listed a price. We can get their current prices and MOQ.
Verify from $29 · written report in 3 business days · 100% refund if not satisfied
About this product
- Materials: See figure
- Size: See Image
- Color: See figure
- Cooling method: Other
- Power source: Other
- Stroke: Other
- Exports to: Mainland China, Africa, Middle East, Southeast Asia, South Asia, Central Asia, USA and Canada, Latin America, Russia, EU, Other European Countries, Japan and South Korea, Hong Kong China, Macao China and Taiwan China, Others
About this product
- Materials: See figure
- Size: See Image
- Color: See figure
- Cooling method: Other
- Power source: Other
- Stroke: Other
- Exports to: Mainland China, Africa, Middle East, Southeast Asia, South Asia, Central Asia, USA and Canada, Latin America, Russia, EU, Other European Countries, Japan and South Korea, Hong Kong China, Macao China and Taiwan China, Others
Product details
| Materials | See figure |
|---|---|
| Size | See Image |
| Color | See figure |
| Cooling method | Other |
| Power source | Other |
| Stroke | Other |
Product details
| Materials | See figure |
|---|---|
| Size | See Image |
| Color | See figure |
| Cooling method | Other |
| Power source | Other |
| Stroke | Other |
From the supplier
performance
Closed torches are mainly used for emergency burning torches in biogas projects, which are used for emergency burning when gas production is too large or equipment maintenance; biogas generated by some industrial projects is burned through torches to meet environmental protection emission requirements; landfill gas is passed through the torches. Actively guide exhaust combustion to achieve safety and deodorization functions
combustion mode
Natural air suction and special ejector are used. Atmospheric combustion closed torches are mainly used for emergency burning torches in biogas projects. Emergency burning occurs when the gas production is too large or equipment is overhauled: biogas generated by some industrial projects is burned through torches. Treatment to meet environmental protection emission requirements; landfill gas is actively discharged and burned through the torch to achieve safety and deodorization functions. Through the added online monitoring module (flow rate, combustion temperature and other parameters), the torch can apply for CDM carbon emission reduction compensation. According to landfill gas treatment specifications and GB50014 drainage specifications, biogas flares should be of closed or internal combustion construction. nbsp;
Main characteristics Import of core components. The dark fire burned. No blower is needed. The ejector is used to achieve "blue fire" and reduce the height of the flame. Double-layer stainless steel combustion chamber or ceramic fiber combustion chamber. Fully automatic ignition and real-time flame monitoring can switch gas tank ignition, pressure ignition, remote ignition, manual ignition,"plug and play" design, and you can install and debug yourself. nbsp;
The main structure consists of main components such as combustion chamber, ejector nozzle, support structure, ignition and flame monitoring system, flame arrestor, main actuator, condensate discharge, PLC control cabinet, etc. The torch adopts a large fully enclosed steel structure with built-in ceramic temperature-resistant modules. The torch further adopts a skid-mounted structure, with all components such as the torch, fan, pipeline, monitoring module and electronic control arranged on the base. The main body of the torch is made of 304 stainless steel, and the combustion chamber is made of double-layer stainless steel or ceramic fiber.& nbsp;
Design parameters Biogas flow range: 30-5000 Nm3/h Biogas combustion calorific value: 4500-6000 kcal/Nm3 Design Biogas pressure: 1-6KPa
The control equipment torch control cabinet is equipped with a PLC control system, and standard software functions can be realized: gas tank ignition, pressure automatic ignition, remote central control ignition, on-site manual ignition, on-site emergency stop; and transmission of torch combustion, valve opening, fault and other operating signals to the upper central control room: The fault signal can be cancelled on site or restarted remotely.
From the supplier
performance
Closed torches are mainly used for emergency burning torches in biogas projects, which are used for emergency burning when gas production is too large or equipment maintenance; biogas generated by some industrial projects is burned through torches to meet environmental protection emission requirements; landfill gas is passed through the torches. Actively guide exhaust combustion to achieve safety and deodorization functions
combustion mode
Natural air suction and special ejector are used. Atmospheric combustion closed torches are mainly used for emergency burning torches in biogas projects. Emergency burning occurs when the gas production is too large or equipment is overhauled: biogas generated by some industrial projects is burned through torches. Treatment to meet environmental protection emission requirements; landfill gas is actively discharged and burned through the torch to achieve safety and deodorization functions. Through the added online monitoring module (flow rate, combustion temperature and other parameters), the torch can apply for CDM carbon emission reduction compensation. According to landfill gas treatment specifications and GB50014 drainage specifications, biogas flares should be of closed or internal combustion construction. nbsp;
Main characteristics Import of core components. The dark fire burned. No blower is needed. The ejector is used to achieve "blue fire" and reduce the height of the flame. Double-layer stainless steel combustion chamber or ceramic fiber combustion chamber. Fully automatic ignition and real-time flame monitoring can switch gas tank ignition, pressure ignition, remote ignition, manual ignition,"plug and play" design, and you can install and debug yourself. nbsp;
The main structure consists of main components such as combustion chamber, ejector nozzle, support structure, ignition and flame monitoring system, flame arrestor, main actuator, condensate discharge, PLC control cabinet, etc. The torch adopts a large fully enclosed steel structure with built-in ceramic temperature-resistant modules. The torch further adopts a skid-mounted structure, with all components such as the torch, fan, pipeline, monitoring module and electronic control arranged on the base. The main body of the torch is made of 304 stainless steel, and the combustion chamber is made of double-layer stainless steel or ceramic fiber.& nbsp;
Design parameters Biogas flow range: 30-5000 Nm3/h Biogas combustion calorific value: 4500-6000 kcal/Nm3 Design Biogas pressure: 1-6KPa
The control equipment torch control cabinet is equipped with a PLC control system, and standard software functions can be realized: gas tank ignition, pressure automatic ignition, remote central control ignition, on-site manual ignition, on-site emergency stop; and transmission of torch combustion, valve opening, fault and other operating signals to the upper central control room: The fault signal can be cancelled on site or restarted remotely.
About the supplier
- ✓Exhibited at 2 recent Canton Fairs
- ✓Foreign Trade Company
- ✓Founded 1999
- ✓1 certificate on file
Manufacturing exhibitors show in Phase 1 of the Canton Fair, 15 to 19 October 2026.
- Exhibited at 2 recent Canton Fairs
- Foreign Trade Company
- Founded 1999
- 1 certificate on file













